Manufacturer:
The Concrete curing temperature data logger kit includes everything you need to start logging the temperature curing process of concrete.
Part Number: Concrete-Kit
Back to Previous Page
Product Files
$848.00 ex GST
i h

Description

The Concrete curing temperature data logger kit includes everything you need to start logging the temperature curing process of concrete.

This kit includes:
1 x UX120-014M 4 Channel Thermocouple Data Logger
1 x CABLE-USBMB USB Cable from Logger to PC.
1 x HB6412 Logger Box Waterproof data logger enclosure
4 x CONCRETE-K-10M, 10m Ready-made Thermocouples complete Miniplugs and 10 extra crimp ferrules so you can cut the used sensor off after the cure and re-use it on the next job.
HOBOware software is a free download from our web site: Here

The HOBO UX120 Thermocouple Logger is a four-channel LCD data logger for measuring and recording temperature and accepts 4 type K temperature sensors via a mini plug.

In addition to accepting four thermocouple probes, the logger features an internal temperature sensor for logging ambient temperatures, further extending the range of capabilities.

The supplied Enclosure is fitted with 4 x Cable Glands for the thermocouple leads and back hooks for storing long cables, standing the box upright or hooking to framework.
This Enclosure has an IP66 Rating (with all glands sealed) and a Transparent cover to see the data logger display.
175(L) x 125(W) x 75(D)mm

Note: Minor assembly required.
The logger is fixed to the metal backing plate with inbuilt magnets
Thermocouples thread through fitted cable glands and plug into the logger.

Monitoring Concrete Curing Temperatures with Data Loggers

HOBO Thermocouple Data Logger UX120 014M

Learn more about the HOBO UX120 Thermocouple Logger, a four-channel LCD data logger for measuring and recording temperature in a broad range of monitoring applications. The logger makes it easy and convenient to record temperatures over a broad range (-260 to 1820⁰ C) and can accept up to four J, K, T, E, R, S, B, or N type probes.


Monitoring Concrete Curing Temperatures with Data Loggers

The country of origin for this product is the United States. To see the full specifications for this product, please see our product manual found under the documentation tab if available

Thermocouple


Type Range Accuracy Resolution
J -210° to 760°C (-346° to 1,400°F) ±0.6°C (±1.08°F) ± thermocouple probe accuracy 0.03°C (0.06°F)
K -260° to 1,370°C (-436° to 2,498°F) ±0.7°C (±1.26°F) ± thermocouple probe accuracy 0.04°C (0.07°F)
T -260° to 400°C (-436° to 752°F) ±0.6°C (±1.08°F) ± thermocouple probe accuracy 0.02°C (0.03°F)
E -260° to 950°C (-436° to 1,742°F) ±0.6°C (±1.08°F) ± thermocouple probe accuracy 0.03°C at (0.05°F)
R -50° to 1,550°C (-58° to 2,822°F) ±2.2°C (±3.96°F) ± thermocouple probe accuracy 0.08°C (0.15°F)
S -50° to 1,720°C (-58° to 3,128°F) ±2.2°C (±3.96°F) ± thermocouple probe accuracy 0.08°C (0.15°F)
B 550° to 1,820°C (1,022° to 3,308°F) ±2.5°C (±4.5°F) ± thermocouple probe accuracy 0.1°C (0.18F)
N -260° to 1,300°C (-436° to 2,372°F) ±1.0°C (±1.8°F) ± thermocouple probe accuracy 0.06°C (0.11°F)

 

 

Internal 10K Thermistor (Temperature):


Plot A Time AccuracyRange (Logging): -20° to 70°C (-4° to 158°F)
Acuracy: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), see Plot A
Resolution: 0.024°C at 25°C (0.04°F at 77°F); see Plot A
Drift: <0.1°C (0.18°F) per year

 

 

Logger


Logger Operating Range
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing); logger accuracy from 0° to 50°C (32° to 122°F)
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification

Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Logging modes: Normal, Burst or Statistics
Memory modes: Wrap when Full or Stop when Full
Start modes: Immediately, Push Button, Date & Time or Next Interval
Stop modes: When Memory Full, Push Button, or Date & Time
Restart mode: Push Button
Time Accuracy - UX120-014MTime accuracy: ±1 minute per month at 25°C (77°F), see Plot B
Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater
Battery type: Two AAA 1.5V alkaline batteries, user replaceable
Memory: 4 MB (1.6 million measurements, maximum)
Download type: USB 2.0 interface
Full memory download time: Approximately 1.5 minutes
LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 10.8 x 5.41 x 2.54 cm (4.25 x 2.13 x 1 in.)
Weight107.5 g (3.79 oz)
Environmental rating: IP50

Description: ce - The CE Marking identifies this product as complying with all relevant directives in the European Union (EU)

HOBOware Software

IMPORTANT: This HOBO data logger requires HOBOware software and a communications cable (see related products below)
HOBOware Software is a FREE download


or Learn more about HOBOware and HOBOware-Pro features

 

Note: This logger also operates with the advanced HOBOware-Pro Software

 


 

Description

The Concrete curing temperature data logger kit includes everything you need to start logging the temperature curing process of concrete.

This kit includes:
1 x UX120-014M 4 Channel Thermocouple Data Logger
1 x CABLE-USBMB USB Cable from Logger to PC.
1 x HB6412 Logger Box Waterproof data logger enclosure
4 x CONCRETE-K-10M, 10m Ready-made Thermocouples complete Miniplugs and 10 extra crimp ferrules so you can cut the used sensor off after the cure and re-use it on the next job.
HOBOware software is a free download from our web site: Here

The HOBO UX120 Thermocouple Logger is a four-channel LCD data logger for measuring and recording temperature and accepts 4 type K temperature sensors via a mini plug.

In addition to accepting four thermocouple probes, the logger features an internal temperature sensor for logging ambient temperatures, further extending the range of capabilities.

The supplied Enclosure is fitted with 4 x Cable Glands for the thermocouple leads and back hooks for storing long cables, standing the box upright or hooking to framework.
This Enclosure has an IP66 Rating (with all glands sealed) and a Transparent cover to see the data logger display.
175(L) x 125(W) x 75(D)mm

Note: Minor assembly required.
The logger is fixed to the metal backing plate with inbuilt magnets
Thermocouples thread through fitted cable glands and plug into the logger.

Monitoring Concrete Curing Temperatures with Data Loggers