OVERVIEW
Measure and reduce your energy costs and increase your sustainability with the VA 570 flow meter. Monitor your consumption and analyse your leakage rate with a stationary flow meter in distribution stations, in front of individual departments or for billing purposes of individual consumers.
Advantages of the VA570 flow meter at a glance:
- Measurement of mass flow, direct output of standard volume flow, without additional measurement of pressure and temperature, possible
- All wetted parts of the VA 570 are made of stainless steel, especially for applications with high demands on cleanliness and surface quality
- The robust aluminum housing is ideally suited for harsh industrial conditions as well as for outdoor installations
- No moving parts, therefore low maintenance
- Vanishingly low pressure loss due to vanishingly low blockage of the diameter
- ATEX or DVGW certification available, thus recommended for gases such as natural gas, hydrogen, biogas, etc.
- Highly accurate at small as well as large flow rates
- Pressure and temperature compensated by the thermal mass flow principle
- Easy installation and removal of the sensor from the measuring section, the measuring section can remain in the line for cleaning or recalibration of the sensor and can simply be closed with a sealing cap
Technical details:
- For velocities up to 224 Nm/s
- Temperature range up to a maximum of 180°C
- Maximum pressure 16 bar, up to 40 bar in PN 40 special version
- Can be used from DN15 to DN 80
- Highly accurate with a precision of ±1.5% or ±1% of the measured value, as well as ±0.3% of the full scale
- 04…20 mA, pulse and one Modbus RTU (RS 485) interface as standard, optional interfaces like two galvanically isolated analog outputs (04…20 mA), Modbus TCP (Ethernet), PoE, M-Bus
- Pressure range up to 40 bar
- IP 67
- Integrated display for showing the measured values
- Settings can be changed via the keys on the display
- Total counter reading can be reset via the display
-
SPECIFICATIONS
Measuring range: up to 50 Nm/s, low-speed version*
up to 92.7 Nm/s, standard version*
up to 185 Nm/s, max. version*
up to 224 Nm/s, high-speed version*
* Measuring range Nm³/h for different pipe diameters and gases, see table measuring ranges flow
* All measured values related to DIN 1343 standard conditions 0° and 1013 mbar ex worksAccuracy:
Accuracy class
(o. M. V. = of measured
value)
(o. F. S. = of full scale)± 1.5% of m.v. ± 0.3 % of f.s.
on request:
± 1.0% of m.v. ± 0.3 % of f.s.Accuracy indications: relative to ambient temperature 22 °C ± 2 °C, system pressure 6 bar Repeatability: 0.25% of m.v. in case of correct mounting (mounting aid, position, inlet section) Measuring principle: Thermal mass flow sensor Response time: t90 < 3 s Operating temperature range sensor tube/display unit: -40…180 °C standard version, sensor tube
-20…70 °C display unit
-20…120 °C for ATEX versionAdjustment possibilities via display, external
hand-held device PI 500, PC Service Software, remote diagnosis:Nm³/h, Nm³/min, Nl/min, l/s, ft/min, cfm, kg/h, kg/min, inner diameter, reference conditions ° C/° F, mbar/ hPa, zero point correction, leak flow volume suppression, scaling analogue output 4…20 mA, pulse/alarm, error codes etc. Outputs: Standard: 1 x 4…20 mA analogue output (not electrically isolated), pulse output, RS 485 (Modbus-RTU) Optional: 2 x 4 … 20 mA active, Modbus TCP, HART, Profibus DP, Profinet, M-Bus Burden: < 500 Ohm Additional average value calculation: for all parameters freely adjustable from 1 minute up to 1 day, e. g. 1/2 hours average value, average day value Protection class: IP67 Material: Die-cast aluminum housing, sensor tube stainless steel 1.4571 Operating pressure: 16 bar, in special version 40 bar Power supply: 18…36 VDC, 5 W Approval: ATEX II 2G Ex db IIC T4 Gb, ATEX II 2D Ex tb IIC T90 °C, Db, DVGW
CS Instruments VA 570 – Thermal mass flow meter for consumption measurement
$0.00 NZD ex GST
Measure and reduce your energy costs and increase your sustainability with the VA 570 flow meter. Monitor your consumption and analyse your leakage rate with a stationary flow meter in distribution stations, in front of individual departments or for billing purposes of individual consumers.