OVERVIEW
Specifically designed for early detection of potential fire risk in pulverizing mills in coal or biomass processes, Millwatch monitors and quickly responds to sudden carbon monoxide (CO) build-up, allowing preventative action to be taken before a hazardous condition develops.
Using AMETEK Land’s unique detection system, Millwatch provides continuous, accurate monitoring of CO levels – improving process safety, protecting expensive mill equipment, and preventing costly downtime from unnecessary shutdowns.
Millwatch continuously extracts sample gases from the mill outlet for a constant, dual-sensor CO measurement. Customisable alarms adapt to individual plant process conditions, while automatic calibration ensures high measurement integrity is maintained 24/7.
Specifically designed for power generation operators who need to improve process safety in mills and pulverisers using coal and biomass fuels, Millwatch ensures the protection of people, plant and process.
Reliable Monitoring
Millwatch has been proven in dozens of applications worldwide, providing enhanced safety and continuous monitoring. The detector’s extractive dual sensor system allows very high stability and automatic detection of calibration drift.
Fast, Continuous Measurements
Millwatch features truly continuous measurement with no multiplexing. The fast response (T90 typically < 50 seconds) to increases in CO levels provides early warning to the operator, enabling prevention of plant damage and personnel injury.
A Rugged Sample System
To ensure maximum lifetime and reliability of the detector, the mill probe uses a large area stainless steel filter and a hardened abrasion shield. Blowback keeps this filter clear, ensuring minimum downtime. Freeze-protected sample lines are available for outdoor applications.
Millwatch is AMETEK Land’s carbon monoxide detector for detection of early-stage combustion in biomass and coal mills.
-
SPECIFICATIONS
Measurement Range CO Measurement Ranges 0-100 up to 2000 ppm in 50 ppm steps Resolution 1 ppm / 1 mg/m3 Optional O2 Ranges 0 – 5 % to 0 – 25 % Calibration Calibration Method Automatic 2-point calibration span and zero User Interface Type LCD with backlight 4 x 20 character, 8 access keys Outputs/Inputs Analog Output 4 to 20 mA isolated current loop for each CO & O2 measurement Relay Outputs 2 x Level Alarms; System OK; Calibration/Maintenance Relating Rating Isolated changeover (Type C) 1 A @ 240 V a.c. or 5 A @ 240 V d.c. Environmental System Enclosure Painted steel, sealed IP65 / NEMA 4 Ambient Temperature 0 to 45 °C / 32 to 113 °F standard;
to -20 °C / -4 °F with optional case heater;
to 50 °C / 122 °F with optional vortex coolerCompliance EMC Conforms to EN-50 081 & EN-50 082 Electrical Safety Conforms to EN-61010-2 Power Power Supply 100 – 120 V a.c. or 190 to 240 V a.c., 50-60 Hz, 300 VA Gas and Air Requirements Instrument Air (cooling) 5 – 10 bar / 70 – 150 psi clean and dry, 300 l/min/10.5 cfm Calibration Gas 100 ppm to 500 ppm CO, balance N2 recommended
2 bar / 30 psi
20 litres (0.7 cu.ft.) per calibration approx.Mechanical Size (H x W x D) 600 x 600 x 350 mm / 24 x 24 x 14 in. Weight 53 kg . 117 lb. Options Twin Stream CO
System Sample Probe and Lines
Heating / Cooling
Z-purge for hazardous area operation
Oxygen measurement (Single Stream only)
Land Millwatch Carbon Monoxide Detectors
$0.00 NZD ex GST
An advanced carbon monoxide detector designed to provide early warning of spontaneous combustion in pulverisers for coal and biomas