OVERVIEW
Seamless Integration with CAN networks
The PyroCAN measures the temperature of a surface and transmits it via CAN Bus using the Raw CAN protocol. The sensor can be connected to a network with more PyroCAN sensors and other types of CAN device. A configurable CAN ID allows it to be connected easily to an existing network. The adjustable emissivity allows a variety of materials to be measured with high accuracy and repeatability.
The PyroCAN series is a range of general purpose infrared temperature sensors (pyrometers) that measure the temperature of surfaces without contact. The temperature is transmitted digitally every 200 ms via a CAN interface. The sensor’s CAN ID and emissivity setting may be changed via a CAN command.
The sensor is suitable for measuring a variety of non-metal surfaces, including painted materials, rubber, plastics, asphalt, soil, plants, organic materials, food and pharmaceuticals. Metals can be measured if they are painted or heavily oxidised.
Features
- Non-contact infrared temperature sensor with CAN Bus interface
- Temperature range: -20°C to 1000°C
- Configurable CAN ID and adjustable emissivity setting
- Raw CAN communications
- Adjustable emissivity setting for measuring a variety of materials
- Fast 200 ms response with high stability
- Stainless steel housing, sealed to IP65
- Ideal for vehicle-based applications in automotive testing, motorsport testing, industry, construction and agriculture, among many others.
- Conforms to industrial EMC standards
Please refer to product images or datasheet for field of view images.
-
APPLICATIONS
Automotive Testing
Multiple sensors can be mounted in various locations around a vehicle during testing, to monitor the surface temperatures of engine blocks, suspension parts, belts and exhausts.
Industrial and agricultural vehicles
The PyroCAN allows temperature monitoring on vehicles throughout industry and agriculture. The process temperature can be accurately monitored without contact, and parts of the vehicle can be monitored with the same sensor.
-
SPECIFICATIONS
General Specifications
Temperature Range -20°C to 1000°C Interface Raw CAN Accuracy ±1% of reading or ±1ºC whichever is greater Repeatability ± 0.5% of reading or ± 0.5°C whichever is greater Emissivity Setting Adjustable via CAN, 0.2 to 1.0 Response Time, t90 200 ms (90% response) Spectral Range 8 to 14 μm Supply Voltage 12 to 24 V DC Supply Current 50 mA max. CAN Protocol Specifications
Baud Rate 250 kbps Data Format 8 bytes total:
Bytes 1-4: Object temperature as floating point
Bytes 5-8: Ambient temperature as floating pointTransmit Interval 200 ms CAN ID range ID can be set between 0 and 255 as a 4-byte unsigned integer Emissivity Adjustable from 0.2 to 1.0 as a 4-byte floating point Mechanical Specifications
Construction Stainless Steel Dimensions 18 mm diameter x 103 mm long Thread Mounting M16 x 1 mm pitch Cable Length 1m (longer lengths available to order) Weight with Cable 95 g Environmental Specifications
Environmental Rating IP65 Ambient Temperature range 0°C to 90°C Relative Humidity 95% max. non-condensing Electromagnetic Compatibility Standards
EN61326-1, EN61326-2-3 (Electrical Equipment for Measurement, Control and Laboratory Use – EMC Requirements – Industrial)